Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Rev. odontol. UNESP (Online) ; 51: e20220043, 2022. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1424239

RESUMO

Introdução: a inovação dos métodos de fotopolimerização foi proposta na tentativa de diminuir o estresse de contração de polimerização das resinas compostas e proporcionar maior conforto ao paciente, reduzindo o tempo de atendimento odontológico. Objetivo: avaliar a microdureza de duas resinas compostas nanoparticuladas submetidas a diferentes técnicas de polimerização. Material e método: quarenta espécimes foram divididos em quatro grupos (n=10) da seguinte forma: Filtek Z350 XT® + técnica imediata (GI); Filtek One Bulkfill® + técnica imediata (GII); Filtek Z350 XT® + técnica de pulso tardio (GIII); Filtek One Bulkfill® + técnica de pulso tardio (GIV). Após o armazenamento em água destilada à temperatura ambiente, os corpos de prova foram direcionados para a medição de microdureza. Utilizou-se teste T para comparação de técnicas e teste Two-Way ANOVA para calcular os efeitos das resinas compostas, técnicas de polimerização e interações referentes à variável dependente (p ≤0,05). Resultado: a resina Filtek Z350 XT® apresentou maior dureza na técnica imediata (GI - 312,45 ± 64,37) e pulso tardio (GIII - 244,50 ± 75,63) comparado à resina Filtek One Bulkfill®, em ambas as técnicas. Observaram-se maiores valores de dureza referentes à técnica imediata, com diferença estatística significativa em relação à resina testada (p = 0,04 - Filtek Z350 XT®; p = 0,03 - Filtek One Bulkfill®). Ambos os fatores isolados (resina e técnicas) apresentaram efeito nos valores de microdureza (p = 0,02 e p < 0,01, respectivamente). Conclusão: a técnica convencional demonstrou atingir maiores valores de dureza quando comparada à técnica de polimerização alternativa.


Introduction: the innovation of photopolymerization methods was proposed in an attempt to reduce the polymerization shrinkage stress of composite resins and also provide more comfort to patient reducing the chair time. The aim of this in vitro study was to assess the microhardness of two nanofilled composite resins subject to different curing techniques. Objective: assess the microhardness of two nanofilled composite resins subject to different curing techniques. Material and method: forty specimens were divided into four groups (N=10) as follows: Filtek Z350 XT® + immediate technique (GI); Filtek One Bulkfill® + immediate technique (GII); Filtek Z350 XT® + delayed pulse technique (GIII); Filtek One Bulkfill® + delayed pulse technique (GIV). After storage in distilled water at room temperature the specimens were assessed for microhardness measurement. T-test was used for comparison of techniques and two-way ANOVA used to calculate the effects of composite resins, curing techniques and their interactions on dependent variable (p set at 0.05). Result: Filtek Z350 XT® resin presented greater hardness on immediate technique (GI - 312,45 ± 64.37) and delayed pulse (GIII - 244,50 ± 75.63) compared to Filtek One Bulkfill® under both techniques. Overall, it was observed greater hardness values under immediate technique with a significant statistical difference apart of tested resin (p = 0.04 - Filtek Z350 XT®; p = 0.03 - Filtek One Bulkfill®). Both isolated factors (resin and techniques) presented effect on microhardness values (p = 0.02 and p < 0.01, respectively). Conclusion: the conventional technique demonstrated to reach higher hardness values when compared to the alternative polymerization technique


Assuntos
Técnicas In Vitro , Análise de Variância , Resinas Compostas , Cura Luminosa de Adesivos Dentários , Testes de Dureza
2.
J Clin Exp Dent ; 11(4): e334-e339, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31110612

RESUMO

BACKGROUND: Nowadays, the use of whitening toothpastes is a common habit, especially among young adults, due to aesthetic appeal. On the other hand, little is known regarding the effects of brushing with those newly dentifrices on wear properties of resin composites. MATERIAL AND METHODS: Thirty specimens of nanoparticle composite resin were fabricated and stored in distilled water for 24 h at 370C. After this, the roughness analysis was performed and submitted to the simulated brushing technique using three types of toothpastes: conventional (GI), and two with whitening effect (GII and GIII) for a period of 15 days, with 2 brushing sessions per day for 2 minutes each. The final surface roughness was analyzed after completing all the brushing cycles and stereoscopic images were taken for each group. The data was analyzed by one-way ANOVA and Tukey-test post hoc for intergroup comparison and the T-test for dependent samples as well (α = 0.05). RESULTS: However showing an increase of roughness for all groups after the brushing cycles (p = 0.01), no statistically significant differences among the groups after simulated brushing was verified (p = 0.17). Yet, just some cracks of the stereoscopic images were shown, demonstrating no distinct visual effects among the studied groups. CONCLUSIONS: After simulated brushing with the whitening toothpastes, similar degree of roughness was verified on the composite resin tested. Key words:Composite resin, toothpastes, whitening.

3.
RGO (Porto Alegre) ; 66(4): 339-344, Oct.-Dec. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-984915

RESUMO

ABSTRACT Objective: evaluate bond strength of a universal adhesive, associated to an extra hydrophobic sealing layer, and compare after three and six months immersed in distilled water. Methods: After ethical approval of the CEP / HUUFMA, 12 human third molars (n = 6) were extracted, which were divided into two groups: SB - control group - selfetching; and SBHidrof - selfetching group associated to the hydrophobic layer (Adhesive layer, 3m ESPE). After incremental restoration with composite resin (Opalis, FGM), the teeth were sliced to obtain specimens (1mm2) and then submitted to the universal test machine (INSTRON 1mm / min.), immediate and after three and six months. The data were submitted to normality (Shapiro Wilk), and comparative Analysis of variance (two ways: technique and time) and Tukey (p <0.05). Results Immediate values showed no statistically significant difference (p> 0.05), but after three and six months of immersion of the specimens, in distilled water, bond strength values were maintained in the group that received the hydrophobic layer (p<0.05). Conclusion: It was observed that, by incorporating a hydrophobic layer on a universal adhesive system, it was possible to preserve dentin adhesion.


RESUMO Objetivo: Avaliar a de resistência de união da interface adesiva associada a uma camada hidrofóbica extra de selamento, e comparar após três e seis meses de armazenamento em água destilada. Métodos: Foram utilizados 12 terceiros molares humanos extraídos hígidos (n=6), que foram divididos em dois grupos, sendo grupo SB - controle - autocondicionante; e grupo SBHidrof - autocondicionante associado à camada hidrofóbica (Adhesive layer, 3m ESPE). Após restauração incremental com resina composta (Opalis, FGM), os dentes foram fatiados para obtenção de espécimes (1mm2) e em seguida, submetidos à máquina de ensaio universal (INSTRON 1mm/min.) imediato e após três e seis meses. Os dados obtidos foram submetidos à normalidade (Shapiro Wilk), e análise comparativa ANOVA (dois fatores: técnica e tempo) e Tukey (p<0,05). Resultados: Nos valores imediatos não houve diferença estatisticamente significante (p>0,05), porém após três e seis meses de imersão dos espécimes, em água destilada, foi observado manutenção dos valores de resistência de união no grupo que recebeu a camada hidrofóbica (p<0,05). Conclusão: Ao incorporar uma camada hidrofóbica sobre um sistema adesivo universal, foi possível preservar a longevidade da adesão dentinária.

4.
J Clin Exp Dent ; 10(3): e206-e211, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29721219

RESUMO

BACKGROUND: The widespread use of mouthwashes, specially in children, is a concern, since the long-term use may modify the topography of dental materials. However, this process still unclear regarding the wear related to infant mouthwashes on glass ionomer cement. Thus, the purpose of this investigation was evaluate the erosive potential of infant mouthwashes on glass ionomer cement specimens. MATERIAL AND METHODS: Forty round-shaped specimens were divided into 4 groups (N=10) and submitted to erosive cycling for 15 days, being exposed 2X/day in the following children's active agents mouthwash solutions: G1- cetylpyridinium chloride, G2- xylitol and triclosan and G3 - Malva sylvestris and xylitol. Prior to cycling, the specimens were submitted to the surface roughness measurement. After erosive cycling, the specimens were reanalyzed, and calculated the increase of roughness (∆Ra). Additionally, it was adopted distilled water as a negative control (G4). As an extra analysis, the mouthwashes had their pH values measured. The results were submitted to T-test and ANOVA followed by Tukey test at 5%. RESULTS: In relation to pH values, G2 presented the most acidic pH value (pH = 6.83) in comparison to other substances. Regarding the comparison of the final roughness values (R) among the groups, it was verified that the mouthwashes showed significant roughness increase in comparison to control group, especially to G3 group (Rf = 1.67 ± 0.14) as well the ΔRa values with statistical difference in comparison to distilled water. Still, with exception of control group outcome, an increase of roughness of each mouthwash was verified after the studied period. CONCLUSIONS: Active agents present in infant mouthwashes were capable of roughness increased of glass ionomer cement surface, demonstrating an erosive potential of this material largely used in pediatric dentistry. Key words:Dental erosion, dental cements, mouthwash.

5.
J Contemp Dent Pract ; 16(8): 643-7, 2015 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-26423500

RESUMO

OBJECTIVE: The aim of this in vivo study was to radiographically evaluate the proximal contour of composite resin restorations performed using different matrix systems. MATERIALS AND METHODS: Patients with premolars needing class II type resin composite restorations involving the marginal ridge were selected. Thirty premolars were selected and randomly divided into three groups (n = 10 each) to receive restorations using different matrix systems: group 1: metal matrix coupled to a carrier matrix and wood wedge (G1-MMW); group 2: sectioned and precontoured metal matrix and elastic wedge (G2-SME); and group 3: a polyester strip and reflective wedge (G3-PMR). After the restorative procedure, bitewing radiographs were performed and analyzed by three calibrated professionals. The quality of the proximal contact and marginal adaptation of the proximal surfaces was classified as either correct or incorrect (undercontour/overcontour). RESULTS: The Pearson Chi-square statistical test (α = 5%) revealed a statistically difference between frequencies of correct and incorrect restorations (α(2) = 6.787, p < 0.05). The group G2 SME produced a higher frequency of correct proximal contours (90%), while G1-MMW and G3-PMR had a ratio of 40% correct and 60% incorrect contours respectively. CONCLUSION: None of the matrix systems was able to prevent the formation of incorrect proximal contours; however, the sectioned and precontoured metal matrix/elastic wedge configuration provided better results as compared to the other groups.


Assuntos
Dente Pré-Molar/cirurgia , Resinas Compostas/química , Ligas Dentárias/química , Materiais Dentários/química , Restauração Dentária Permanente/classificação , Bandas de Matriz/classificação , Adulto , Dente Pré-Molar/lesões , Colagem Dentária , Preparo da Cavidade Dentária , Adaptação Marginal Dentária , Restauração Dentária Permanente/instrumentação , Feminino , Humanos , Masculino , Propriedades de Superfície
6.
Braz Dent J ; 26(4): 368-73, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26312974

RESUMO

The aim of this study was evaluate in vitro the influence of simplified adhesive systems (etch-and-rinse and self-etching) and 1.23% acidulated phosphate fluoride (APF) on the microshear bond strength (µ-SBS) of composite resins on primary molars and incisors. Forty primary molars and forty incisors vestibular enamel was treated with either the self-etching Clearfil SE Bond (CSE, Kuraray) or etch-and-rinse Adper Single Bond 2 (SB2, 3M/ESPE) adhesive system. Each group was subdivided based on the prior treatment of the enamel with or without the topical application of 1.23% APF. Thereafter, matrices were positioned and filled with composite resin and light cured. After storage in distilled water at 37 ± 1°C for 24 h, the specimens were submitted to µ-SBS in a universal testing machine. Kruskal-Wallis and Mann-Whitney tests (p < 0.05) showed that the prior application of 1.23% APF led to a significant reduction in bond strength. The type of adhesive exerted no significant influence bond strength. In the inter-group analysis, however, significantly bond strength reduction was found for the incisors when CSE was employed with APF. Adhesive failure was the most common type of fracture. The bond strength was affected by the prior application of 1.23% APF and type of tooth.


Assuntos
Adesivos , Colagem Dentária , Fluoretos/farmacologia , Incisivo , Dente Molar , Humanos , Teste de Materiais
7.
Braz. dent. j ; 26(4): 368-373, July-Aug. 2015. tab
Artigo em Inglês | LILACS | ID: lil-756398

RESUMO

The aim of this study was evaluate in vitro the influence of simplified adhesive systems (etch-and-rinse and self-etching) and 1.23% acidulated phosphate fluoride (APF) on the microshear bond strength (μ-SBS) of composite resins on primary molars and incisors. Forty primary molars and forty incisors vestibular enamel was treated with either the self-etching Clearfil SE Bond (CSE, Kuraray) or etch-and-rinse Adper Single Bond 2 (SB2, 3M/ESPE) adhesive system. Each group was subdivided based on the prior treatment of the enamel with or without the topical application of 1.23% APF. Thereafter, matrices were positioned and filled with composite resin and light cured. After storage in distilled water at 37±1°C for 24 h, the specimens were submitted to μ-SBS in a universal testing machine. Kruskal-Wallis and Mann-Whitney tests (p<0.05) showed that the prior application of 1.23% APF led to a significant reduction in bond strength. The type of adhesive exerted no significant influence bond strength. In the inter-group analysis, however, significantly bond strength reduction was found for the incisors when CSE was employed with APF. Adhesive failure was the most common type of fracture. The bond strength was affected by the prior application of 1.23% APF and type of tooth.

.

O objetivo deste estudo foi avaliar a influência dos sistemas adesivos simplificados (condicionamento ácido total e auto-condicionante) e fluorfosfato acidulado a 1,23% (FFA) na resistência de união ao microcisalhamento (μ-RUC) de resinas compostas em molares e incisivos decíduos. O esmalte vestibular de quarenta molares e quarenta incisivos decíduos foi tratado com Clearfil SE Bond (CSE, Kuraray) ou Adper Single Bond 2 (SB2, 3M/ESPE). Cada grupo foi subdividido com base no tratamento prévio do esmalte com ou sem aplicação tópica de FFA a 1,23%. Em seguida, matrizes foram posicionadas e preenchidas com resina composta e posterior fotopolimerização. Depois da armazenagem em água destilada a 37±1 °C por 24 h, os espécimes foram submetidos ao μ-RUC em uma máquina de ensaio universal. Teste Kruskal-Wallis e Mann-Whitney (p<0,05) mostraram que a aplicação prévia de FFA a 1,23% levou a uma redução significativa na resistência de união. O tipo de adesivo não exerceu influência significativa na resistência de união. Na análise intergrupos, entretanto, redução significativa na resistência de união foi encontrada para os incisivos quando CSE foi empregado sem FFA. Falha adesiva foi o tipo de fratura mais comum. A resistência de união foi afetada pela aplicação de FFA a 1,23% e tipo de dente.

.


Assuntos
Humanos , Adesivos , Colagem Dentária , Fluoretos/farmacologia , Incisivo , Dente Molar , Teste de Materiais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...